Version 7.0
121
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.28
SONET Section LOS Alarm
This alarm applies only to the Mediant 3000.
SONET Section LOS Alarm
Description
This alarm indicates that LOS or AIS condition is present on SONET no
#m.
The field 'sonetSectionCurrentStatus' in the sonetSectionCurrentTable will
have a value of sonetSectionLOS (2).
SNMP Alarm
acSonetSectionLOSAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.39
Alarm Source
Interfaces#0/Sonet#<m>, where
m
is the SONET interface number
Alarm Type
communicationsAlarm
Probable Cause
lossOfSignal
Alarm Severity
Condition
<text>
Corrective Action
Critical (default)
LOS condition is
present on SONET
no #n
SONET-Section
LOS
3.
Make sure the fiber optic
cable is plugged in correctly.
4.
Make sure it's not damaged.
5.
Make sure its remote end is
correctly connected and
undamaged.
6.
Make sure that configuration
of the remote port is correct.
Note that the
'sonetSectionCurrentStatus' field
in the sonetSectionCurrentTable
will have a value
sonetSectionLOS (2)
Cleared
LOS condition is not
present
-
-