Version 7.0
125
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.32 Dial Plan File Replaced Trap
This alarm applies to the Analog Series and Mediant Digital Series.
Dial Plan File Replaced
Description
This event informs that the dial plan file has been successfully replaced.
SNMP Alarm
acDialPlanFileReplaced
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.45
Alarm Title
Dial Plan File Replaced
Default Severity
Indeterminate
Event Type
Other (0)
Probable Cause
Other (0)
Status Change
Condition
Successful dial plan file replacement
Trap Text
Dial plan file replacement complete.
3.4.33
Hitless Update Event
Hitless Update Event
Description
A Notification trap that is sent out at the beginning and the end of a Hitless SW
update. Failure during the process will also instigate the trap.
SNMP Alarm
acHitlessUpdateStatus
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.48
Alarm Title
Hitless Update event
Alarm Source
Automatic Update
Alarm Type
Other
Probable
Cause
Other
Alarm Severity
Condition
<text>
Corrective Action
Indeterminate
A notification trap sent at the
beginning
and
end
of a hitless
software update. Failure
during
the software update also activates
the trap.
Hitless
Update
Event
The corrective action for each
condition is described below.
Hitless: Start software upgrade.
Corrective action is not required.
Hitless fail: Invalid cmp file file -
missing Version parameter.
Replace the cmp file with a valid
one.