Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
Corrective Action
•
When this alarm is raised, you cannot reload configuration or
firmware files to the device as it has already been connected to the
EMS. Instead download these files to the device using the Software
Manager and then use the 'Software Upgrade' action.
OR
•
Remove the device from the EMS and then reconnect it i.e. repeat
the pre-provisioning process.
Media Gateways
All gateways managed by EMS.
3.3
SEM Alarms
3.3.1
SEM – Failed Calls Alarm
SEM – Failed Calls Alarm
Description
This alarm is raised when the failed calls threshold is crossed and is
cleared when the failed calls ratio returns below the threshold value.
The description field includes the info: Failed X1% of calls, X2 of X3 calls.
SNMP Alarm
acSEMRuleFailedCallsAlarm
SNMP OID
1.3.6.1.4.1.5003.9.20.3.2.0.30
Alarm Title
SEM - Failed Calls Alarm
Alarm Source
SEM/<Device Name> or SEM/<Link Name> (According to provisioned
scope)
alarm type
Quality of service alarm.
Probable Cause
The minimum or maximum threshold is crossed.
Severity
According to provisioned thresholds: critical, major or clear
Additional Info
Critical or Major severity threshold is Y%:
•
Critical Threshold:
5
% of calls (default)
•
Major Threshold:
3
% of calls (default
Corrective Action
Investigate the source (device or link) of the failed calls.
3.3.2
SEM – Voice Quality Alarm
SEM – Voice Quality Alarm
Description
This alarm is raised when the poor quality calls threshold is crossed and
is cleared when the poor quality calls ratio returns below the threshold
value.
The description field includes the info: Poor Quality X1% of calls, X2 of
X3 calls.
SNMP Alarm
acSEMRulePoorQualityCallsAlarm
SNMP OID
1.3.6.1.4.1.5003.9.20.3.2.0.31