Version 7.0
47
Performance Monitoring and Alarms
Performance Monitoring and Alarms
2. Performance Monitoring Parameters
2.6.5
Tab: MGCP Control
Frame: Gateway System Monitoring (Real-Time), Tab: MGCP Control
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
[Mgcp] Num of Active
Contexts
RT
Gauge This attribute indicates the Current number of MGCP
active contexts incorporating at least 1 Termination, per
TPM.
Mib name: acPMActiveContextCountValMgcp
[MGCP] RSIP Command
- Disconnected
RT
Counter Counts the Disconnected service change commands
sent (excluding retransmission) to the current MGC,
during the last interval.
Mib name:
acPMMGCPRsipReasonCountValDisconnected
[MGCP] RSIP Command
- Restart
RT
Counter Counts the Restart service change commands
(excluding retransmission) sent to the current MGC,
during the last interval.
Mib name: acPMMGCPRsipReasonCountValRestart
[MGCP] RSIP Command
- Forced
RT
Counter Counts the Forced service change commands sent
(excluding retransmission) to the current MGC, during
the last interval.
Mib name: acPMMGCPRsipReasonCountValForced
[MGCP] RSIP Command
- Graceful
RT
Counter Counts the Graceful service change commands sent
(excluding retransmission) to the current MGC, during
the last interval.
Mib name: acPMMGCPRsipReasonCountValGraceful
[MGCP] RSIP Command
- Cancel Graceful
RT
Counter Counts the Cancel Graceful restart in progress
commands sent (excluding retransmission) to the
current MGC during the current interval.
Mib name:
acPMMGCPRsipReasonCountValCancelGraceful
Success [MGCP]
Endpoint Configuration
Command
RT
Counter This attribute counts the number of successful Endpoint
Conf commands, from the beginning of the current
collection interval.
Mib name:
acPMMGCPCommandSuccessCountTotalAdd
Success [MGCP] Create
Connection Command
RT
Counter This attribute counts the number of successful Create
Connection commands, from the beginning of the
current collection interval.
Mib name:
acPMMGCPCommandSuccessCountTotalMove