Version 7.0
17
Performance Monitoring and Alarms
Performance Monitoring and Alarms
2. Performance Monitoring Parameters
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
Path CVs
RT
Gauge The counter associated with the number of Coding
Violations encountered by a SONET/SDH Path in the
current 15 minute interval.
Mib name: sonetPathCurrentCVs
Path UASs
RT
Gauge The counter associated with the number of Unavailable
Seconds encountered by a Path in the current 15
minute interval.
Mib name: sonetPathCurrentUASs
2.4
Frame: Gateway System Monitoring (Configuration)
2.4.1
Tab: System IP
Frame: Gateway System Monitoring (Configuration), Tab: System IP
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
Number of Outgoing
KBytes
HIST
Counter Counts the total number of outgoing Kbytes (1000
bytes) from the interface during the last interval.
Mib name: acPMNetUtilKBytesVolumeTx
Number of Incoming
KBytes
HIST
Counter Counts the total number of Kbytes (1000 bytes)
received on the interface, including those received in
error, during the last interval.
Mib name: acPMNetUtilKBytesVolumeRx
Number of Outgoing Pkts HIST
Counter Counts the total number of outgoing Packets from the
interface during the last interval.
Mib name: acPMNetUtilPacketsVolumeTx
Number of Incoming Pkts HIST
Counter Counts the total number of Packets received on the
interface, including those received in error, during the
last interval.
Mib name: acPMNetUtilPacketsVolumeRx
Number of Incoming
Discarded Pkts
HIST
Counter Counts the total number of malformed IP Packets
received on the interface during the last interval. These
are packets which are corrupted or discarded due to
errors in their IP headers, including bad checksums,
version number mismatch, other format errors, time-to-
live exceeded, errors discovered in processing their IP
options, etc.
Mib name: acPMNetUtilDiscardedPacketsVal