Performance Monitoring and Alarms
104
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.11
System Component Overloaded
System Component Overloaded
Description
This alarm is raised when there is an overload in one or more of the
system's components.
SNMP Alarm
acBoardOverloadAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.11
Alarm Title
System Component Overloaded
Alarm Type
Other
Alarm Source
'GWAPP'
Probable Cause
Other
Severity
Major / Clear
Additional Info1,2,3
-
3.4.12
Active Alarms Table Overflow
Active Alarms Table Overflow
Description
This alarm is raised when there are too many alarms to fit into the active
alarm table. The status stays major until reboot as it denotes a possible
loss of information until the next reboot. If an alarm was raised when the
table was full, it is possible that the alarm is active, but does not appear
in the active alarm table.
SNMP Alarm
acActiveAlarmTableOverflow
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.12
Alarm Title
[Event] Active Alarm Table Overflow
Alarm Type
Processing Error Alarm
Alarm Source
MG
Probable Cause
resourceAtOrNearingCapacity (43)
Severity
Major
Additional Info1,2,3
-
Corrective Action
Some alarm information may have been lost, but the ability of the device
to perform its basic operations has not been impacted. A reboot is the
only way to completely clear a problem with the active alarm table.
Contact your first-level group.