Version 7.0
151
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
Major
When Proxy Set
includes more than one
proxy IP with
redundancy and
connection to one of
them is lost.
Proxy Set %d: Proxy
lost. looking for
another proxy
1.
Ping the proxy server. If there is no
ping, contact your proxy provider.
The probable reason is the proxy is
down.
2.
Ping between the proxy and
AudioCodes device. If there is no
ping, the problem could be a
network/router issue.
3.
If you have more than one device
connected to this same proxy, check
if there are more AudioCodes
devices with the same Alarm. If this
is the case, this could confirm that
this is not AudioCodes device issue.
4.
Check if routing via the redundant
proxy is operating correctly. If it is,
then this could mean that it's not a
network issue.
5.
Contact AudioCodes support center
(
) and
send a syslog and network capture
for this issue.
Cleared
When connection to
proxy is available again
Proxy found. ip:<IP
address>:<port #>
Proxy Set ID %d
-
3.4.4
Redundant Board Alarm
Redundant Board Alarm
Description
The active board sends a notification when an alarm or notification is
raised on the redundant board.
SNMP Alarm
acRedundantBoardAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.97
Alarm Title
Alarm Source
Alarm Type
Notification
Probable Cause
Severity
Additional Info
Corrective Action
Содержание Mediant 3000 TP-6310
Страница 2: ......
Страница 10: ......
Страница 11: ...Version 7 0 11 OAM Guide Performance Monitoring and Alarms 1 Introduction This page is intentionally left blank...
Страница 12: ......
Страница 116: ...Performance Monitoring and Alarms 116 Document LTRT 32111 Mediant 3000 with TP 6310 Cleared HA system is active...