Version 7.0
75
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.2
EMS Alarms
3.2.1
EMS Trap Receiver Binding Error
EMS Trap Receiver Binding Error
Textual Description
This alarm is generated during server startup if an error occurs
indicating that the SNMP trap receiver port is already taken.
SNMP OID
acEMSSnmpCannotBindError- 1.3.6.1.4.1.5003.9.20.3.2.0.1
AlarmTitle
[Event] EMS Trap Receiver Binding Error
ItuAlarmType
Environmental Alarm
AlarmSource
EMS Server
Probable Cause
Application Subsystem Failure
Severity
Critical
Additional Info
-
Corrective Action
Run netstats command to verify which application uses the alarms
reception port (by default UDP post 162).
•
EMS application: If it's busy, check which application uses this port.
If it's not freed by the EMS application, restart the EMS Server
application according to the equipment installation manual.
•
Other network management application: change the EMS
application and all managed gateways' default alarm reception
ports.
Media Gateways
All the gateways managed by the EMS
Содержание Mediant 3000 TP-6310
Страница 2: ......
Страница 10: ......
Страница 11: ...Version 7 0 11 OAM Guide Performance Monitoring and Alarms 1 Introduction This page is intentionally left blank...
Страница 12: ......
Страница 116: ...Performance Monitoring and Alarms 116 Document LTRT 32111 Mediant 3000 with TP 6310 Cleared HA system is active...