Performance Monitoring and Alarms
74
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.1.7
DS3 Line Status
DS3 Line Status
Description
From RFC 3896 (Definitions of Managed Objects for the DS3/E3 Interface
Type. O.Nicklass, Ed.. September 2004): A dsx3LineStatusChange trap is
sent when the value of an instance of dsx3LineStatus changes. It can be
utilized by an NMS to trigger polls. When the line status change results in a
lower level line status change (i.e., ds1), then no traps for the lower level are
sent.
SNMP Alarm
[Event] dsx3LineStatusChange
SNMP OID
1.3.6.1.2.1.10.30.15.0.1
Alarm Title
DS3 Line Status
Alarm Type
Communication Alarm
Alarm Source
Trunk# (number of trunk)
Probable Cause
Other
Severity
Major on raise, Clear on clear
Additional Info1,2,3
Updated DS3 Line Status.
This variable indicates the Line Status of the interface. It contains loopback
state information and failure state information. The dsx3LineStatus is a bit
map represented as a sum, therefore it can represent multiple failures and a
loopback (see dsx3LoopbackConfig object for the type of loopback)
simultaneously. The dsx3NoAlarm must be set if and only if no other flag is
set. If the dsx3loopbackState bit is set, the loopback in effect can be
determined from the dsx3loopbackConfig object.
The various bit positions are:
1
dsx3NoAlarm
No alarm present
2
dsx3RcvRAIFailure
Receiving Yellow/Remote Alarm Indication
4
dsx3XmitRAIAlarm
Transmitting Yellow/Remote Alarm
Indication
8
dsx3RcvAIS
Receiving AIS failure state
16 dsx3XmitAIS
Transmitting AIS
32 dsx3LOF
Receiving LOF failure state
64 dsx3LOS
Receiving LOS failure state
128 dsx3LoopbackState Looping the received signal
256 dsx3RcvTestCode
Receiving a Test Pattern
512 dsx3OtherFailure
Any line status not defined here
1024 dsx3UnavailSigState
Near End in Unavailable Signal State
2048 dsx3NetEquipOOS
Carrier Equipment Out of Service
Corrective Action
-