Version 7.0
131
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.38
IPv6
Description
This alarm indicates when an IPv6 address already exists or an IPv6
configuration failure has occurred. The description generated is "IP
interface alarm. IPv6 Configuration failed, IPv6 will be disabled".
SNMP Alarm
acIPv6ErrorAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.53
Default Severity
Critical
Alarm Source
System#0/Interfaces#<n>.
Alarm Type
operationalViolation
Probable Cause
communicationsProtocolError
Additional Info
Status stays critical until reboot. A clear trap is not sent.
Corrective Action
Find a new IPV6 address and reboot.
Alarm Severity
Condition
<text>
Corrective Action
Critical (default)
Bad IPv6
address
(already
exists)
IP interface alarm: IPv6
configuration failed, IPv6
will be disabled.
Find a new IPV6 address.
Reboot the device.
Stays 'Critical' until
reboot.
A 'Clear' trap is not sent.
After the
alarm is
raised.
-
-