Version 7.0
155
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.8
Proxy Connectivity
Proxy Connectivity
Description
Sent when a connection to a specific proxy in a specific Proxy Set
is down. The trap is cleared when the proxy connections is up.
SNMP Alarm
acProxyConnectivity
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.102
Alarm Source
System#0
Alarm Text
Proxy Set Alarm <text>
Alarm Type
communicationsAlarm
Probable Cause
Network issue (connection fail due to network/routing failure).
Proxy issue (proxy is down).
AudioCodes device issue.
Alarm Severity
Condition
<text>
Corrective Action
Indeterminate
When connection to
the proxy server is
lost.
Proxy Server
<IP
address>:<port>
is now OUT OF
SERVICE
1.
Ping the proxy server. If there is no
ping, contact your proxy provider. The
probable reason is the proxy is down.
2.
Ping between the proxy and
AudioCodes device. If there is no
ping, the problem could be a
network/router issue.
3.
If you have more than one device
connected to this same proxy, check if
there are more AudioCodes devices
with the same trap event. If this is the
case, this could confirm that this is not
AudioCodes device issue.
4.
Contact AudioCodes support center
(
) and send
a syslog and network capture for this
issue.
Cleared
When connection to
the proxy is available
again
Proxy Server
<IP
address>:<port>
is now IN
SERVICE
-