Performance Monitoring and Alarms
138
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.46
SONET Path Unequipped Alarm
This alarm applies only to Mediant 3000 TP-6310.
SONET Path Unequipped Alarm
Description
This alarm is issued when the Unequipped condition is present on the
SONET Path #m.
SNMP Alarm
acSonetPathUnequippedAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.64
Alarm Title
SONET Path Unequipped Alarm
Alarm Source
Interfaces#0/Path#<m>
Alarm Type
communicationsAlarm
Probable Cause
receiveFailure
Severity
Critical / clear
Additional Info
Corrective Action
Equip the path on the far-end
3.4.47
SONET Path Signal Label Alarm
This alarm applies only to Mediant 3000 TP-6310.
SONET Path Signal Label Alarm
Description
This alarm is issued when the Signal Label condition is present on the
SONET Path #m.
SNMP Alarm
acSonetPathSignalLabelMismatchAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.65
Alarm Title
SONET Path Signal Label Alarm
Alarm Source
Interfaces#0/Path#<m>
Alarm Type
communicationsAlarm
Probable Cause
receiveFailure
Severity
Critical / clear
Additional Info
Corrective Action
Set the transmit path signal label on the far-end to either "VT Structured
STS1 SPE" (02) or "Asynchronous Mapping DS3" (04).