Performance Monitoring and Alarms
120
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.27
SONET Section LOF Alarm
This alarm applies only to the Mediant 3000.
SONET Section LOF Alarm
Description
This alarm indicates that a LOF condition is present on SONET no#m.
The field 'sonetSectionCurrentStatus' in the sonetSectionCurrentTable
will have a value of sonetSectionLOF (4).
SNMP Alarm
acSonetSectionLOFAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.38
Default Severity
Critical
Alarm Source
Interfaces#0/Sonet#<m>, where
m
is the SONET interface number
Alarm Type
communicationsAlarm
Probable Cause
lossOfFrame
Alarm Severity
Condition
<text>
Corrective Action
Critical
LOF condition is
present on SONET
no.n
SONET-Section
LOF
Make sure the framing format on
the port matches the format
configured on the line.
Note that the
'sonetSectionCurrentStatus' field
in the sonetSectionCurrentTable
will have a value
sonetSectionLOF(4)
Cleared
LOF condition is not
present
LOF
-