background image

 

R-ETM100

GATEWAY Modul ModBuS oVER TCP

cod. 80126C Edit 04 - 08/2011 - ENG

INSTALLATION AND OPERATION MANUAL

2 • INSTALLATION AND CONNECTION

This section contains the instructions necessary for correct 

installation of the GIloGIK II  into the machine control panel 

or the host system and for correct connection of the system 

power supply, inputs, outputs and interfaces.

Before proceeding with installation read the following 

warnings carefully! 

Remember that lack of observation of these warnings 

could lead to problems of electrical safety and electroma-

gnetic compatibility, as well as invalidating the warranty.

Qualified staff 

the installation and use of the system and components are only reserved 

at qualified staff.

Conform use 

the system and relative components are usable exclusively to the use 

previewed in the manual

In order to guarantee a correct and sure operation are indispensable that 

the product comes transported, stored correctly, installed, and controlled 

second the previewed modalities.

Suitable for use in pollution degree 2 environment. 

Open type equipment

Electrical power supply

•  the GILOGIK II is NOT equipped with an On/Off switch: the user must

  provide a two-phase disconnecting switch that conforms to the required

  safety standards (CE marking), to cut off the power supply upstream of

  the system. The switch must be located in the  vicinity of the system and

  must be within easy reach of the operator.

  One switch may control more than one systems.

•  To make sure that the system very is connected to earth second the

  detailed lists of the relative understood one it.

•  if the system is used in applications with risk of damage to persons,

  machinery or materials, it is essential to connect it up to auxiliary 

  security equipment. It is advisable to make sure that alarm signals are

  also triggered during normal operation.

  The dispositif must NOT be installed in flammable or explosive 

  environments; it may be connected to equipment operating in such

  atmospheres only by means of appropriate and adequate types of 

  interface, conforming to the applicable safety standards

Notes Concerning Electrical Safety and Electromagnetic 

Compatibility:

•  CE MARKING:  EMC Conformity  (electromagnetic compatibility) 

  in accordance with EEC Directive 2004/108/CE. The GILOGIK II

  system is mainly designed to operate in industrial environments,

  installed on the switchboards or control panels of productive process

  machines or plants.

  Norm of applicable product EN 61131-2.

  The Declaration of conformity  is available on GEFRAN web:

 www.gefran.com

•  UL listed standard: UL508 file E198546

•  BT Conformity (low tension)

  in accordance with Directive LVD 2006/95/CE.

  Advice for Correct Installation for EMC

Module  power supply

•  Supply with class 2 device

•  The power supply to the modules on the switchboards must always

  come directly from an isolation device with a fuse.

•  The electronic instruments and electromechanical power devices such

  as relays, contactors, solenoid valves, etc., must always be powered 

by

  separate lines.

•  When the power supply is strongly disturbed by the commutation of

  transistor or power units or motors, an isolation transformer should be

  used, earthing the screen.

•  It is essential that the plant has a good earth connection:

  - the voltage between neutral and earth must not be > 1V

  - the Ohmic resistance must be < 6

;

•  In the proximity of high frequency generators or arc welders,  use 

  adequate filters.

•  The power supply lines must be separate from the instrument input 

and output ones.

GEFRAN S.p.A. declines all responsibility for any damage 
to persons or property caused by tampering, neglect, 
improper use or any use which does not conform to the 
characteristics of the controller and to the indications 
given in these Instructions for Use.

I

1 • MAIN FEATURES

•  Complete control of R-BUS(x) back plane

•  Ethernet interface, Modbus protocol over TCP

•  Power supply of backplane

3

 80126C_MHW_R-ETM100_08-2011_ENG

Отзывы: