Advanced Administration
70
UDM-0102 and UDM-RX02 Operation/Reference Guide
Backing up the Hub Configuration File
1.
Run your TFTP client. If using the Windows client, move to step 2.
2.
Start a command session on the PC.
3.
Change to the directory where the Hub Protocol file is to be stored on the PC.
For example:
cd\udm
and
cd\protocol
.
4.
Type in the following command at the prompt, observing the parameters below:
TFTP -i [
IP address
] get ixxxxx.hub
or
TFTP -i [
IP address
] get sxxxxx.hub
Where
ixxxxxx.hub
is the name of the Hub configuration file.
The file name must start with an
i
or an
s
.
If the name of the Hub Protocol file is not known typing in i or s followed by any logical characters will
find the file, as there is only one protocol file in the UDM Hub.
A file name starting with either i or s will retrieve that file. Use a name that will identify the protocol file
for the project. For example:
imyprotocol.hub
is an acceptable name.
5.
When complete, close the command window.
Restoring the Hub Configuration File
1.
Run your TFTP client. If using the Windows client, move to step 2.
2.
Start a command session on the PC. Change to the directory where the Hub Configuration file is to be
stored on the PC.
For example:
cd\udm
and
cd\protocol
.
3.
Type in the following command at the prompt, observing the parameters below:
TFTP -i [IP address] put ixxxxx.hub
-or-
TFTP -i [IP address] put sxxxxx.hub
Where
ixxxxxx.hub
is the name of the Hub protocol file.
All Hub protocol file names start with an
i
or
s
.
4.
When complete, close the command window.
When the protocol file is restored, it will usually automatically associate correctly with the configuration file
when it is restored.
However, it is wise to check each UDM port using the Web interface to verify the correct protocol is assigned.
Upgrading Input Controllers
1.
Run the TFTP client.
2.
Start a command session on the PC. Change to the directory where the .ROM files are stored on the PC.
For example:
cd\Hub
3.
Type in the following command at the prompt observing the parameters below:
TFTP –i [IP address] PUT uXXXXXXX.022
Содержание Endeleo Multi-Format Receiver UDM-RX02
Страница 4: ......
Страница 8: ...Important Safety Markings UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 26: ...UDM 0102 Wiring and Connections 12 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 32: ...UDM RX02 Wiring and Connections 18 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 50: ...Configuration Setup Page 36 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 58: ...Configuration Devices Page 44 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 64: ...Configuration Schedule Page 50 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 88: ...Advanced Administration 74 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 90: ...UDM RC10 Remote Control 76 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 94: ...Video Compensation 80 UDM 0102 and UDM RX02 Operation Reference Guide ...