Advanced Administration
67
UDM-0102 and UDM-RX02 Operation/Reference Guide
Advanced Administration
Overview
System upgrades of the UDM-0102 can be performed following consultation with AMX support. Upgrade
files can be downloaded from the AMX web site.
Tools required to perform system upgrades include;
TFTP client
Necessary files. Files that represent possible firmware updates include:
UDM-0102 Firmware (file format =
c<id>.rom
)
Web Firmware (file format =
f<id>.rom
or
f<id>.dat
)
Port Firmware (for output ports, not input ports - file format =
p<id><3 digit port #>.rom
)
Bootloader Firmware (file format =
b<id>.rom
)
UDM-RX02 Firmware (file format =
c<id>.rom
)
Working knowledge of UDM-0102 and UDM-RX02.
Establishing a TFTP Session with the Hub and/or Receiver
The Serial port on the UDM-0102 and UDM-RX02 is an RJ12 connector, and requires a RS01
DB9-to-RJ12 adapter cable (FG-RS01) to connect to a PC for Terminal control.
On the UDM-0102, the Serial port is located on the front panel, and is labelled "
10101
".
On the UDM-RX02, the Serial port is located on the rear panel, and is labelled “
SERIAL
”.
1.
Use the RS01 DB9-to-RJ12 adapter cable to connect an available DB9 Serial port on the PC to the RJ12
Serial port on either the UDM-0102 or the UDM-RX02.
2.
Ensure the TFTP client software has been installed on the PC, and is configured to use default Serial
communication settings:
3.
Start a Command Line session on the PC and run the TFTP client.
Copying the Hub Configuration File
Copying the Hub Configuration file permits the Administrator to backup key data entered by Administrators
such as Input names, Port names, Devices and the Hub setup.
To backup the Hub Configuration file;
1.
Run the TFTP client.
2.
Start a command session on the PC. Change to the directory where the Hub Configuration file is to be
stored on the PC e.g.
cd\Hub
.
The Controller Firmware and the Web Firmware
must always be the same version
.
Never upgrade one without also upgrading the other to the same version number.
Default Serial Settings
Baud Rate:
9600
Data Bits:
8
Parity:
None
Stop Bits:
1
Flow Control:
None
Ensure the TFTP client has been installed on the PC which will be used to send files
to the Hub. Install TFTP client if necessary, consult with AMX support as to the
appropriate client.
Содержание Endeleo Multi-Format Receiver UDM-RX02
Страница 4: ......
Страница 8: ...Important Safety Markings UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 26: ...UDM 0102 Wiring and Connections 12 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 32: ...UDM RX02 Wiring and Connections 18 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 50: ...Configuration Setup Page 36 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 58: ...Configuration Devices Page 44 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 64: ...Configuration Schedule Page 50 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 88: ...Advanced Administration 74 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 90: ...UDM RC10 Remote Control 76 UDM 0102 and UDM RX02 Operation Reference Guide ...
Страница 94: ...Video Compensation 80 UDM 0102 and UDM RX02 Operation Reference Guide ...