5-15
towards 1, the step response will slow down, but the overshoot and settling time will be
smaller. A default damping factor of 0.707 is typically an optimal choice that gives a
system a response that blends a small amount overshoot with fast response and quick
settling time.
5.4.3.3.
Use VFF
If this box is checked, AutoTune will set VFF to 1.
5.4.3.4.
Calculate AFFGAIN
If this box is checked, AutoTune will calculate an AFFGAIN