Figure 5-22. Cross-Section of the DS16020/16030 Amplifier
b. Make rough adjustments to the potentiometers on the Aerotech DS16020/16030
servo amplifier as shown in Figure 5-23, then run the axis at its maximum
speed. This maximum speed will be provided to the user by Aerotech if the
user purchased a complete system from Aerotech. Otherwise, the user will
have to calculate the maximum speed. While running the axis at maximum
speed, adjust the input potentiometer on the amplifier so that the torque plot in
AerTune (torque actually indicates velocity when in the velocity command
mode) indicates approximately 26,200 (8 volts).
Figure 5-23.
Amplifier Potentiometer Layout
TP1–TP5
RCN
Fuse
LED
TP1 = Current Feedback (Torque) (3A/volt)
TP3 = Tach
TP4 = Common
TP5 = Velocity Command
TP2 = Current Command (3A/volt)
Servo Gain
Current Limit
Balance
Tachometer
Input
LED
Turn it Full CW
INITIAL SETTINGS
Turn it Full CW
Turn it Midway
Turn it Full CCW, then back it off in
the CW direction 1/4 of a turn
Based upon Peak Curren rating of motor
DS16020 = 20A max, DS16030 = 30A max
Содержание UNIDEX 600 Series
Страница 19: ...Table of Contents U600 User s Guide xviii Aerotech Inc Version 1 4...
Страница 27: ...Preface U600 User s Guide xxvi Aerotech Inc Version 1 4...
Страница 163: ...AerPlot U600 User s Guide 6 6 Aerotech Inc Version 1 4...
Страница 169: ...AerReg U600 User s Guide 8 4 Aerotech Inc Version 1 4...
Страница 177: ...AerPlotIO U600 User s Guide 10 4 Aerotech Inc Version 1 4...
Страница 179: ...Filter U600 User s Guide 11 2 Aerotech Inc Version 1 4...
Страница 219: ...PrmSetup U600 User s Guide 13 2 Aerotech Inc Version 1 4...
Страница 223: ...Glossary of Terms U600 User s Guide A 4 Aerotech Inc Version 1 4...
Страница 353: ......