U600 User’s Guide
Setup Wizard
Version 1.4
Aerotech, Inc.
12-23
If the HomeOffsetInch machine parameter is set to a non-zero value with axis
calibration active, the axis may not stop on the marker at the completion of the home
cycle. If it desired to do so, for a positioning test, you must temporarily disable axis
calibration, within the axis configuration wizard.
If a virtual axis is homed, it will immediately set the position to the home position,
rather than simulating any motion.
Homing will cancel all fixture offsets and presets.
When using the CNC (MMI600), the HomeOffset task parameter is used. However,
for Library invoked homing, the HOMEOFFSET axis parameter is used. If using
both CNC and Library interfaces simultaneously, the user must use both of these
parameters.
If an axis is in the Simulation, Dry Run, or Machine Lock modes when it is homed,
the home command will never complete, because the axis does not move in these
modes.
Homing will disable normalcy, cutter offset and cutter radius compensation modes.
Содержание UNIDEX 600 Series
Страница 19: ...Table of Contents U600 User s Guide xviii Aerotech Inc Version 1 4...
Страница 27: ...Preface U600 User s Guide xxvi Aerotech Inc Version 1 4...
Страница 163: ...AerPlot U600 User s Guide 6 6 Aerotech Inc Version 1 4...
Страница 169: ...AerReg U600 User s Guide 8 4 Aerotech Inc Version 1 4...
Страница 177: ...AerPlotIO U600 User s Guide 10 4 Aerotech Inc Version 1 4...
Страница 179: ...Filter U600 User s Guide 11 2 Aerotech Inc Version 1 4...
Страница 219: ...PrmSetup U600 User s Guide 13 2 Aerotech Inc Version 1 4...
Страница 223: ...Glossary of Terms U600 User s Guide A 4 Aerotech Inc Version 1 4...
Страница 353: ......