U600 User’s Guide
Parameters
Version 1.4
Aerotech, Inc.
C-89
C.4.86.
NormalcyX
This task parameter specifies which task axis is used for the X axis of the normalcy plane.
This axis must be a linear type. The NormalcyX and NormalcyY parameters are used to
determine the normalcy plane. When enabled the normalcy axis will maintain a normal
(perpendicular) orientation to the contoured motion projected onto the normalcy plane.
This parameter is 0 based, i.e.; the 1st axis (X) is represented as 0.
C.4.87.
NormalcyY
This task parameter specifies which task axis is used for the Y axis of the normalcy plane.
This axis must be a linear type. The NormalcyX and NormalcyY parameters are used to
determine the normalcy plane. When enabled the normalcy axis will maintain a normal
(perpendicular) orientation to the contoured motion projected onto the normalcy plane.
This parameter is 0 based, i.e.; the 2nd axis (Y) is represented as 1.
C.4.88.
Number
This task parameter specifies the current task number (from 0 through 3). This value can
be used by a CNC program to determine on which task it is running. This is a read-only
parameter.
C.4.89.
NumTaskAxisPts
This task parameter specifies the total number of task axis point variables to allocate for
the task. Each task axis point uses 132 bytes of controller memory.
C.4.90.
NumTaskDoubles
This task parameter specifies the total number of task double variables to allocate for the
task. Each task double allocated uses up 12 bytes of controller memory
C.4.91.
NumTaskStrings
This task parameter specifies the total number of task string32 variables to allocate for the
task. Each task string32 allocated uses up 34 bytes of controller memory.
C.4.92.
ROReq1
The ROReq1 task parameter is a pointer to a 16-bit virtual register output that is used by
the UNIDEX 600 MMI to request a desired action from the controller, to be handled by
the user. Request words are broken into individual bits, each bit represents a request for
an action. The controller will request the appropriate action. It is the user’s responsibility
to respond to this request and to clear the bit from this register once acted upon. The
following table shows the actions that may be requested via this parameter. Setting this
parameter to –1, disables this mode. See the RoReq1Mask task parameter for specifying
only those requests, which you wish to respond to.
Содержание UNIDEX 600 Series
Страница 19: ...Table of Contents U600 User s Guide xviii Aerotech Inc Version 1 4...
Страница 27: ...Preface U600 User s Guide xxvi Aerotech Inc Version 1 4...
Страница 163: ...AerPlot U600 User s Guide 6 6 Aerotech Inc Version 1 4...
Страница 169: ...AerReg U600 User s Guide 8 4 Aerotech Inc Version 1 4...
Страница 177: ...AerPlotIO U600 User s Guide 10 4 Aerotech Inc Version 1 4...
Страница 179: ...Filter U600 User s Guide 11 2 Aerotech Inc Version 1 4...
Страница 219: ...PrmSetup U600 User s Guide 13 2 Aerotech Inc Version 1 4...
Страница 223: ...Glossary of Terms U600 User s Guide A 4 Aerotech Inc Version 1 4...
Страница 353: ......