U600 User’s Guide
Setup Wizard
Version 1.4
Aerotech, Inc.
12-25
12.9.
Configure the Drive Interface States
Specify the active state for the axis and drive interface signals. The user may configure
the active state of the following signals.
0.
Drive Shutdown
(output to drive)
0x1
1.
AUX (Mode) Output
(output to drive)
0x2
2.
CW limit Switch
(input from drive)
0x4
3.
CCW limit Switch
(input from drive)
0x8
4.
Home limit Switch
(input from drive)
0x10
5.
Drive Fault
(input from drive)
0x20
The value specified is a bit-mask where only the specified bits are valid. Setting a bit to
one implies the input or output is active high. Refer to Section 2.5. Drive Signals in the
Users Guide for more information.
The easiest way to configure these signals via the IOLEVEL axis parameter is to view the
state of the signals via the AerStat.exe utility. Knowing the state of the signal and viewing
the state via AerStat will allow you to toggle the appropriate bits in the IOLEVEL axis
parameter to correct the state.
Figure 12-17.
The Drive Interface Configuration Screen (via the IOLEVEL)
Be sure to set the CW, CCW, and Drive Fault bits in the FAULTMASK axis parameter to
enable the detection of these faults, then set the bits in the appropriate mask parameters
(DISABLEMASK, HALTMASK, AUXMASK, ABORTMASK, INTMASK, and
BRAKEMASK) for actions to occur on these faults.
Содержание UNIDEX 600 Series
Страница 19: ...Table of Contents U600 User s Guide xviii Aerotech Inc Version 1 4...
Страница 27: ...Preface U600 User s Guide xxvi Aerotech Inc Version 1 4...
Страница 163: ...AerPlot U600 User s Guide 6 6 Aerotech Inc Version 1 4...
Страница 169: ...AerReg U600 User s Guide 8 4 Aerotech Inc Version 1 4...
Страница 177: ...AerPlotIO U600 User s Guide 10 4 Aerotech Inc Version 1 4...
Страница 179: ...Filter U600 User s Guide 11 2 Aerotech Inc Version 1 4...
Страница 219: ...PrmSetup U600 User s Guide 13 2 Aerotech Inc Version 1 4...
Страница 223: ...Glossary of Terms U600 User s Guide A 4 Aerotech Inc Version 1 4...
Страница 353: ......