Name
Type
Description
TRIPZ5
BOOLEAN
Trip in any phase or phases from zone 5 - zone
direction
TRIPZRV
BOOLEAN
Trip in any phase or phases from zone RV - reverse
dir.
STARTZ1
BOOLEAN
Start in any phase or phases from zone 1 - forward
direction
STNDZ1
BOOLEAN
Start in any phase or phases from zone 1 - any
direction
STARTZ2
BOOLEAN
Start in any phase or phases from zone 2 - forward
direction
STL1Z2
BOOLEAN
Start in phase L1 from zone 2 - forward direction
STL2Z2
BOOLEAN
Start in phase L2 from zone 2 - forward direction
STL3Z2
BOOLEAN
Start in phase L3 from zone 2 - forward direction
STNDZ2
BOOLEAN
Start in any phase or phases from zone 2 - any
direction
STARTZ3
BOOLEAN
Start in any phase or phases from zone 3 - zone
direction
STNDZ3
BOOLEAN
Start in any phase or phases from zone 3 - any
direction
STARTZ4
BOOLEAN
Start in any phase or phases from zone 4 - zone
direction
STNDZ4
BOOLEAN
Start in any phase or phases from zone 4 - any
direction
STARTZ5
BOOLEAN
Start in any phase or phases from zone 5 - zone
direction
STNDZ5
BOOLEAN
Start in any phase or phases from zone 5 - any
direction
STARTZRV
BOOLEAN
Start in any phase or phases from zone RV -
reverse dir.
STL1ZRV
BOOLEAN
Start in phase L1 from zone RV - reverse direction
STL2ZRV
BOOLEAN
Start in phase L2 from zone RV - reverse direction
STL3ZRV
BOOLEAN
Start in phase L3 from zone RV - reverse direction
STNDZRV
BOOLEAN
Start in any phase or phases from zone RV - any
direction
STARTND
BOOLEAN
Fault detected in any phase or phases - any
direction
STNDL1
BOOLEAN
Fault detected in phase L1 - any direction
STNDL2
BOOLEAN
Fault detected in phase L2 - any direction
STNDL3
BOOLEAN
Fault detected in phase L3 - any direction
STFWL1
BOOLEAN
Fault detected in phase L1 - forward direction
STFWL2
BOOLEAN
Fault detected in phase L2 - forward direction
STFWL3
BOOLEAN
Fault detected in phase L3 - forward direction
STFWPE
BOOLEAN
Fault with earth connection detected - forward
direction
STRVL1
BOOLEAN
Fault detected in phase L1 - reverse direction
STRVL2
BOOLEAN
Fault detected in phase L2 - reverse direction
Table continues on next page
Section 7
1MRK502052-UEN B
Impedance protection
230
Technical manual
Содержание Relion REG670
Страница 1: ...Relion 670 series Generator protection REG670 2 0 IEC Technical manual ...
Страница 2: ......
Страница 44: ...38 ...
Страница 58: ...52 ...
Страница 80: ...74 ...
Страница 106: ...100 ...
Страница 482: ...476 ...
Страница 548: ...542 ...
Страница 570: ...564 ...
Страница 600: ...594 ...
Страница 608: ...602 ...
Страница 630: ...624 ...
Страница 862: ...856 ...
Страница 1094: ...1088 ...
Страница 1226: ...1220 ...
Страница 1250: ...1244 ...
Страница 1297: ...1291 ...