Name
Function
block
SPA
address
Description
ExcOpen=00,
ExcClose=01, so on.
SCSWI02
1 I 5130
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI02
1 I 5152
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI04
1 I 5177
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI05
1 I 5201
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI06
1 I 5225
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI07
1 I 5249
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI08
1 I 5274
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI09
1 I 5298
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI10
1 I 5322
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI11
1 I 5346
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI12
1 I 5370
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI13
1 I 5394
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI14
1 I 5418
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI15
1 I 5442
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI16
1 I 5466
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI17
1 I 5490
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI18
1 I 5514
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI19
1 I 5536
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI20
1 I 5562
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI21
1 I 5585
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI22
1 I 5610
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI23
1 I 5634
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI24
1 I 5658
SPA parameters for operate
(Open/Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI25
1 I 5682
SPA parameters for operate
(Open/Close) command
Table continues on next page
1MRK 502 066-UUS B
Section 18
Station communication
1145
Technical manual
Содержание Relion 670 series
Страница 1: ... RELION 670 SERIES Generator protection REG670 Version 2 1 ANSI Technical manual ...
Страница 2: ......
Страница 48: ...42 ...
Страница 62: ...56 ...
Страница 182: ...176 ...
Страница 692: ...686 ...
Страница 726: ...720 ...
Страница 1014: ...1008 ...
Страница 1242: ...1236 ...
Страница 1362: ...1356 ...
Страница 1386: ...1380 ...
Страница 1422: ...1416 ...
Страница 1431: ...1425 ...