10 Output Assemblies (Converter Consumes)
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
69
Name
Description
D1000: NetRef
R1000: -
D1000: Voltage command from network
0: Depends on
b1-01
1: Voltage command from network
R1000: -
D1000: Voltage Reference
R1000: -
D1000: Voltage Reference
Sets converter voltage reference.
Voltage reference data: Voltage reference/2VS (VS: Voltage scale)
Setting range: 0 - FFFF (Hex.)
Example: setting a reference of 4096 with a voltage scale of 2:
Voltage reference data = 4096/2
2
= 1024 = 400 (Hex.)
Unit depends on
o1-03
.
R1000: -
◆
(Vendor Specific Yaskawa Electric (YE) Assy) Speed/Torque Control Output -
101 (0x65)
Output Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
101
0
0
Multi-
Function
Input 8
Multi-
Function
Input 7
Multi-
Function
Input 6
Multi-
Function
Input 5
Multi-
Function
Input 4
Multi-
Function
Input 3
D1000: -
R1000:
Forced Run
D1000: Run
R1000: Auto
Run
1
Multi-
Function
Digital
Output 3
Multi-
Function
Digital
Output 2
Multi-
Function
Digital
Output 1
-
-
-
Fault Reset
External Fault
1
2
D1000: Voltage Reference (Low Byte)
R1000: -
3
D1000: Voltage Reference (High Byte)
R1000: -
Name
Description
D1000: Run
R1000: Auto Run
D1000: Run converter
0: Stop
1: Run
R1000: Run converter in auto
0: Stop
1: Auto Run
D1000: -
R1000: Forced Run
D1000: -
R1000: Force run converter
0: Stop
1: Force Run
Multi-Function Input 3
Terminal S3 Function Input
0: Terminal S3 Function [H1-03] OFF
1: Terminal S3 Function [H1-03] ON
Multi-Function Input 4
Terminal S4 Function Input
0: Terminal S4 Function [H1-04] OFF
1: Terminal S4 Function [H1-04] ON
Multi-Function Input 5
Terminal S5 Function Input
0: Terminal S5 Function [H1-05] OFF
1: Terminal S5 Function [H1-05] ON
Multi-Function Input 6
Terminal S6 Function Input
0: Terminal S6 Function [H1-06] OFF
1: Terminal S6 Function [H1-06] ON
Multi-Function Input 7
Terminal S7 Function Input
0: Terminal S7 Function [H1-07] OFF
1: Terminal S7 Function [H1-07] ON
Multi-Function Input 8
Terminal S8 Function Input
0: Terminal S8 Function [H1-08] OFF
1: Terminal S8 Function [H1-08] ON
External Fault
External Fault EF0
0: -
1: External Fault [EF0]
Fault Reset
Fault Reset
0: -
1: Fault Reset