11 Input Assemblies (Converter Produces)
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
81
Name
Description
NetRef
Voltage command is from network
0: Voltage command is not from network
1: Voltage command is from network
State
Contains the value from the Control Supervisor (Class 0x29) Instance 1 Attribute 6.
Voltage Actual
Actual Converter Voltage
Monitors the converter output voltage.
Speed actual data: Output Voltage x 2VS (VS: Voltage scale)
Setting range: 0 - FFFF (Hex.)
For example, when output voltage of 1024 with a voltage scale of 2:
Voltage actual data = 1024 x 2
2
= 4096 = 1000 (Hex.)
◆
(Vendor Specific Yaskawa Electric (YE) Assy) Speed/Torque Status Input - 151
(0x97)
Input Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
151
0
0
Faulted
Alarm
Ready
During Run -
Operation
Ready
Reset
During
Regenerative
Operation
-
Running
1
-
-
Multi-
Function
Digital
Output 3
Multi-
Function
Digital
Output 2
Multi-
Function
Digital
Output 1
LOCAL/
REMOTE
Uv
oPE
1
2
Output Voltage (Low Byte)
3
Output Voltage (High Byte)
2
4
-
5
-
3
6
D1000: Current Actual (Low Byte)
R1000: -
7
D1000: Current Actual (High Byte)
R1000: -
Name
Description
Running
Running
0: Stop
1: Running
During Regenerative Operation
During Regenerative Operation
0: Converter not in regenerative operation
1: Converter in regenerative operation
Reset
Reset
0: -
1: Reset
During Run - Operation Ready
During Run - Operation Ready
0: Not Ready
1: Ready
Ready
Ready
0: Not Ready
1: Ready
Alarm
Alarm
0: No Alarm
1: Alarm
Faulted
Faulted
0: No Fault
1: Fault
oPE
oPE
0: -
1: oPExx
Uv
Undervoltage
0: -
1: Undervoltage
LOCAL/REMOTE
Run command is from network
0: Run command is not from network