9 Input Assemblies (Drive Produces)
54
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
Byte
Write Success
Read Success
Write Failure
Read Failure
Invalid Function Code
Function
Code Equals
Zero
3
0
Read Data (High Byte)
0
0
0
0
4
0
Read Data (Low Byte)
Error Code
Error Code
1
0
Table 9.2 Error Replies - 150
Error Code
Description
0x01
Invalid Function Code
0x02
Invalid Register Number
0x21
Upper/Lower Limit Error
0x22
Write Mode Error
Option generated busy event. The MEMOBUS/Modbus requested operation is in the process loop but the drive is not done
yet.
Writing
“
Enter
”
when drive is running.
Attempt to write data that is read only.
Attempt to write a parameter when drive is running.
During a CPF03 event attempting to write to registers other than A1-00 to A1-05, E1-03, o2-04.
0x23
Writing Error during Undervoltage
Attempting to write during a drive Uv [undervoltage] event.
0x24
Writing Error during Parameter Processing
Attempting to write while the drive is storing data.
Note:
Refer to the MEMOBUS/Modbus Data Table in Appendix C of the drive Technical Manual for a list of monitor data using the
MEMOBUS/Modbus message area.
◆
(Vendor Specific Yaskawa Electric (YE) Assy) Speed/Torque Status Input - 151
(0x97)
Input Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
151
0
0
Faulted
Alarm
Ready
Speed Agree
Reset
REV Running
ZSP
Running
1
ZSV
-
Multi-
Function
Digital
Output 3
Multi-
Function
Digital
Output 2
Multi-
Function
Digital
Output 1
LOCAL/
REMOTE
Uv
oPE
1
2
Output Frequency (Low Byte)
3
Output Frequency (High Byte)
2
4
Torque Actual (Low Byte)
5
Torque Actual (High Byte)
3
6
Current Actual (Low Byte)
7
Current Actual (High Byte)
Name
Description
Running
Running
0: Stop
1: Forward or Reverse Running
ZSP
Zero Speed
0: Running
1: Stop or DC Injection Braking
REV Running
Reverse Running
0: Not Reverse Running
1: Reverse Running
Reset
Reset
0: -
1: Reset
Speed Agree
Speed Agree
0: -
1: Speed actual at speed reference
Ready
Ready
0: Not Ready