11 Input Assemblies (Converter Produces)
86
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
Name
Description
0: -
1: Undervoltage
LOCAL/REMOTE
Run command is from network
0: Run command is not from network
1: Run command is from network
Multi-Function Digital Output 1
Terminal M1/M2 (varies by converter model)
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Multi-Function Digital Output 2
Terminal M3/M4 (varies by converter model)
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when H2-02 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Multi-Function Digital Output 3
Terminal M5/M6 (varies by converter model)
0: M5/M6 OFF
1: M5/M6 ON
This function is enabled only when H2-03 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Output Voltage
Converter Output Voltage
Voltage Command
Converter Voltage Command
D1000: Output Current
R1000: -
D1000: Actual Output Current
Monitors the converter output current.
Unit: 0.01A
Unit is not affected by Current Scale CS.
R1000: -
Terminal A1 Input
MEMOBUS/Modbus (0x46)
Monitor parameter U1-13
Main Circuit DC Voltage
Main Circuit DC Voltage
Monitor parameter U1-07
Error Code
U2-01 converted using fault code table.
F7-33 Alarm Code
Programmable: MEMOBUS/Modbus (0x7F)
D1000: F7-34 Output Power
R1000: F7-34 Not Used
D1000: Programmable: MEMOBUS/Modbus (0x47)
Monitor parameter U1-08
R1000: -
F7-35 Terminal A2 Input
Programmable: MEMOBUS/Modbus (0x4F)
Monitor parameter U1-14
F7-36 Terminal S1 - S12
Programmable: MEMOBUS/Modbus (0x49)
Monitor parameter U1-10
F7-37 Terminal A3 Input
Programmable: MEMOBUS/Modbus (0x50)
F7-38 Not Used
-
F7-39 NetRef (Status)
Voltage command is from network
0: Voltage command is not from network
1: Voltage command is from network
F7-39 Not Used
-
F7-40 Converter Software Version
Programmable: MEMOBUS/Modbus (0x4D)
Monitor parameter U1-25
F7-41 Not Used
-
F7-42 Not Used
-
Possible extended error codes are listed in
and
. If an error occurs, extended error code 0x02
(Register number failure) is usually set.