11 Input Assemblies (Converter Produces)
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
85
Input Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R1000: -
7
14
Terminal A1 Input (Low Byte)
15
Terminal A1 Input (High Byte)
8
16
Main Circuit DC Voltage (Low Byte)
17
Main Circuit DC Voltage (High Byte)
9
18
Error Code (Low Byte)
19
Error Code (High Byte)
10
20 - 21
Parameter [F7-33], Default: Alarm Code
11
22 - 23
D1000: Parameter [F7-34], Default: Output Power
R1000: Parameter [F7-34], Default: Not Used
12
24 - 25
Parameter [F7-35], Default: Terminal A2 Input
13
26 - 27
Parameter [F7-36], Default: Terminal S1 - S8 Input
14
28 - 29
Parameter [F7-37], Default: Terminal A3 Input
15
30 - 31
Parameter [F7-38], Default: Not Used
16
32
-
-
-
-
-
-
Parameter
[F7-39] (Low
Byte),
Default:
NetCtrl
Parameter
[F7-39] (Low
Byte),
Default:
NetRef
33
Parameter [F7-39] (High Byte), Default: Not Used
17
34 - 35
Parameter [F7-40], Default: Converter Software Version
18
36 - 37
Parameter [F7-41], Default: Not Used
19
38 - 39
Parameter [F7-42], Default: Not Used
20
40
-
-
-
-
-
-
Assy. 116 F7-
32 Error
Assy. 116 F7-
31 Error
41
Assy. 116 F7-
30 Error
Assy. 116 F7-
29 Error
Assy. 116 F7-
28 Error
Assy. 116 F7-
27 Error
Assy. 116 F7-
26 Error
Assy. 116 F7-
25 Error
Assy. 116 F7-
24 Error
Assy. 116 F7-
23 Error
21
42
-
-
-
-
-
-
Assy. 166 F7-
42 Error
Assy. 166 F7-
41 Error
43
Assy. 166 F7-
40 Error
Assy. 166 F7-
39 Error
Assy. 166 F7-
38 Error
Assy. 166 F7-
37 Error
Assy. 166 F7-
36 Error
Assy. 166 F7-
35 Error
Assy. 166 F7-
34 Error
Assy. 166 F7-
33 Error
Name
Description
Running
Running
0: Stop
1: Running
During Regenerative Operation
During Regenerative Operation
0: Converter not in regenerative operation
1: Converter in regenerative operation
Reset
Reset
0: -
1: Reset
During Run - Operation Ready
During Run - Operation Ready
0: Not Ready
1: Ready
Ready
Ready
0: Not Ready
1: Ready
Alarm
Alarm
0: No Alarm
1: Alarm
Faulted
Faulted
0: No Fault
1: Fault
oPE
oPE
0: -
1: oPExx
Uv
Undervoltage