10 Output Assemblies (Converter Consumes)
72
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
Output Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
116
0
0
Multi-
Function
Input 8
Multi-
Function
Input 7
Multi-
Function
Input 6
Multi-
Function
Input 5
Multi-
Function
Input 4
Multi-
Function
Input 3
D1000: -
R1000:
Forced Run
D1000: Run
R1000: Auto
Run
1
Multi-
Function
Digital
Output 3
Multi-
Function
Digital
Output 2
Multi-
Function
Digital
Output 1
-
-
-
Fault Reset
External Fault
1
2
D1000: Voltage Reference (Low Byte)
R1000: -
3
D1000: Voltage Reference (High Byte)
R1000: -
2
4
-
5
-
3
6
-
7
-
4
8
Reserved
9
-
-
-
-
Multi-
Function
Input 12
Multi-
Function
Input 11
Multi-
Function
Input 10
Multi-
Function
Input 9
5
10
-
-
-
-
-
-
NetCtrl
D1000:
NetRef
R1000: -
11
Reserved
6
12
Analog Output 1 (Low Byte)
13
Analog Output 1 (High Byte)
7
14
Analog Output 2 (Low Byte)
15
Analog Output 2 (High Byte)
8
16
Digital Outputs (Low Byte)
17
Digital Outputs (High Byte)
9
18
Reserved
19
Reserved
10
20 - 21
Programmable Bytes [F7-23], Default: Not Used
11
22 - 23
Programmable Bytes [F7-24], Default: Not Used
12
24 - 25
Programmable Bytes [F7-25], Default: Not Used
13
26 - 27
Programmable Bytes [F7-26], Default: Not Used
14
28 - 29
Programmable Bytes [F7-27], Default: Not Used
15
30 - 31
Programmable Bytes [F7-28], Default: Not Used
16
32 - 33
Programmable Bytes [F7-29], Default: Not Used
17
34 - 35
Programmable Bytes [F7-30], Default: Not Used
18
36 - 37
Programmable Bytes [F7-31], Default: Not Used
19
38 - 39
Programmable Bytes [F7-32], Default: Not Used
20 - 21
40 - 43
Reserved
Name
Description
D1000: Run
R1000: Auto Run
D1000: Run converter
0: Stop
1: Run
R1000: Run converter in auto
0: Stop
1: Auto Run
D1000: -
R1000: Forced Run
D1000: -
R1000: Force run converter
0: Stop
1: Force Run
Multi-Function Input 3
Terminal S3 Function Input
0: Terminal S3 Function [H1-03] OFF