10 Output Assemblies (Converter Consumes)
66
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
Name
Description
oPE
oPE
0: -
1: oPExx
Uv
Undervoltage
0: -
1: Undervoltage
LOCAL/REMOTE
Run command is from network
0: Run command is not from network
1: Run command is from network
Multi-Function Digital Output 1
Terminal M1/M2 (varies by drive model)
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Multi-Function Digital Output 2
Terminal M3/M4 (varies by drive model)
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when H2-02 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Multi-Function Digital Output 3
Terminal M5/M6 (varies by drive model)
0: M5/M6 OFF
1: M5/M6 ON
This function is enabled only when H2-03 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Output Frequency
Actual Drive Speed
Monitors drive output frequency.
Unit depends on o1-03.
Unit is not affected by Speed Scale SS.
Dynamic Inputs
Contains the data to be read from the MEMOBUS/Modbus address defined in the given parameter. A value of 0 in the given
parameter means it will return the default data as defined in the table above.
10
Output Assemblies (Converter Consumes)
Note:
The convention in this manual is from the PLC perspective. As such, an assembly is called an
“
Output Assembly
”
when outputted from
the PLC and received by this node. This section details
“
Output Assemblies
”
that are
“
Consumed
”
by the converter.
◆
EtherNet/IP Basic Speed Control Output - 20 (0x14)
Output Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
20
0
0
-
-
-
-
-
Fault Reset
-
D1000: Run
R1000: Auto
Run
1
-
1
2
D1000: Voltage Reference (Low Byte)
R1000: -
3
D1000: Voltage Reference (High Byte)
R1000: -