SERVOPACK Overload Protection Characteristics (400 V Models)
The overload detection level is set for hot start conditions with a SERVOPACK surrounding air tempera-
ture of 55°C.
An overload alarm (A.710 or A.720) will occur if overload operation that exceeds the overload protection
characteristics shown in the following diagram (i.e., operation on the right side of the applicable line) is
performed.
The actual overload detection level will be the detection level of the connected SERVOPACK or Servo
Motor that has the lower overload protection characteristics.
In most cases, that will be the overload protection characteristics of the Servo Motor.
Note: The above overload protection characteristics do not mean that you can perform continuous duty operation with an
output of 100% or higher.
For a Yaskawa-specified combination of SERVOPACK and Servo Motor, maintain the effective torque (or effective
force) within the continuous duty zone of the torque-motor speed characteristic (or force-motor speed characteris-
tics) of the Servo Motor.
100
200
10000
1000
100
10
1
SERVOPACK Model:
SGD7W-2R6D, -5R4D
Detection time (s)
SERVOPACK output current
(continuous output current ratio) (%)
Instantaneous maximum output current
(Instantaneous maximum output current)
Continuous output current
(Continuous output current)
× 100%
Summary of Contents for SGM7J-A5A
Page 1: ...yaskawa com SIGMA 7 AC Servo Drives and Motors Technical Supplement...
Page 18: ...18...
Page 21: ...SGMMV 4 SGM7J 18 SGM7A 54 SGM7P 116 SGM7G 134 Rotary Servo Motors...
Page 133: ...Rotary Servo Motors SGM7A 115 Rotary Servo Motors...
Page 151: ...Rotary Servo Motors SGM7P 133 Rotary Servo Motors...
Page 206: ...Rotary Servo Motors SGM7G 188...
Page 223: ...Direct Drive Servo Motors SGM7F With Core Inner Rotor 205 Direct Drive Servo Motors...
Page 251: ...Direct Drive Servo Motors SGM7D With Core Outer Rotor 233 Direct Drive Servo Motors...
Page 276: ...Direct Drive Servo Motors SGMCS Small Capacity Coreless or Medium Capacity with Core 258...
Page 409: ...Linear Servo Motors Recommended Linear Encoders and Cables 391 Cables and Peripheral Devices...
Page 435: ...ST2F Sigma Trac II Linear Stages 418 Sigma Trac II Linear Stages...
Page 495: ...SERVOPACKs 7W Two axis MECHATROLINK III Communications Reference SERVOPACKs 477 SERVOPACKs...
Page 516: ...SERVOPACKs SERVOPACK External Dimensions 498...
Page 547: ...SERVOPACK Cables 530 SERVOPACK Peripheral Devices 540 SERVOPACK Cables Peripherals...
Page 557: ...SERVOPACK Cables Peripherals SERVOPACK Cables 539 Cables and Peripheral Devices...
Page 599: ...Appendices Capacity Selection for Servo Motors 581 Appendices...
Page 615: ...Appendices Capacity Selection for Regenerative Resistors 597 Appendices...
Page 617: ...Appendices International Standards 599 Appendices...
Page 620: ......
Page 621: ......