SERVOPACKs
-7S Single-axis Analog Voltage/Pulse Train Reference SERVOPACKs
426
*1. This is the net value at the rated load.
*2. This value is for the optional JUSP-RA04-E Regenerative Resistor Unit.
*3. This value is for the optional JUSP-RA05-E Regenerative Resistor Unit.
Single-phase, 200 VAC
*
This is the net value at the rated load.
Model SGD7S-
470A
550A
590A
780A
Maximum Applicable Motor Capacity [kW]
6.0
7.5
11
15
Continuous Output Current [Arms]
46.9
54.7
58.6
78.0
Instantaneous Maximum Output Current [Arms]
110
130
140
170
Main
Circuit
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current [Arms]
*1
29
37
54
73
Control Power Supply
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Power Supply Capacity [kVA]
*1
10.7
14.6
21.7
29.6
Power Loss
*1
Main Circuit Power Loss [W]
279.4
357.8
431.7
599.0
Control Circuit Power Loss [W]
33
33
48
48
External Regenerative Resistor Unit
Power Loss [W]
180
*2
180
*3
350
*3
350
*3
Total Power Loss [W]
312.4
390.8
479.7
647.0
External Regenera-
tive Resistor Unit
External Regenera-
tive Resistor Unit
Resistance [
]
6.25
*2
3.13
*3
3.13
*3
3.13
*3
Capacity [W]
880
*2
1760
*3
1760
*3
1760
*3
Minimum Allowable External Resistance
[
]
5.8
2.9
2.9
2.9
Overvoltage Category
III
Model SGD7S-
R70A
R90A
1R6A
2R8A
5R5A
Maximum Applicable Motor Capacity [kW]
0.05
0.1
0.2
0.4
0.75
Continuous Output Current [Arms]
0.66 0.91 1.6
2.8
5.5
Instantaneous Maximum Output Current [Arms]
2.1
3.2
5.9
9.3
16.9
Main Circuit
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current [Arms]*
0.8
1.6
2.4
5.0
8.7
Control Power Supply
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Power Supply Capacity [kVA]*
0.2
0.3
0.6
1.2
1.9
Power Loss*
Main Circuit Power Loss [W]
5.1
7.3
13.5
24.0
43.8
Control Circuit Power Loss [W]
17
17
17
17
17
Built-in Regenerative Resistor Power
Loss [W]
-
-
-
-
8
Total Power Loss [W]
22.1
24.3
30.5
41.0
68.8
Regenerative
Resistor
Built-In Regener-
ative Resistor
Resistance [
]
-
-
-
-
40
Capacity [W]
-
-
-
-
40
Minimum Allowable External Resis-
tance [
]
40
40
40
40
40
Overvoltage Category
III
Summary of Contents for SGM7J-A5A
Page 1: ...yaskawa com SIGMA 7 AC Servo Drives and Motors Technical Supplement...
Page 18: ...18...
Page 21: ...SGMMV 4 SGM7J 18 SGM7A 54 SGM7P 116 SGM7G 134 Rotary Servo Motors...
Page 133: ...Rotary Servo Motors SGM7A 115 Rotary Servo Motors...
Page 151: ...Rotary Servo Motors SGM7P 133 Rotary Servo Motors...
Page 206: ...Rotary Servo Motors SGM7G 188...
Page 223: ...Direct Drive Servo Motors SGM7F With Core Inner Rotor 205 Direct Drive Servo Motors...
Page 251: ...Direct Drive Servo Motors SGM7D With Core Outer Rotor 233 Direct Drive Servo Motors...
Page 276: ...Direct Drive Servo Motors SGMCS Small Capacity Coreless or Medium Capacity with Core 258...
Page 409: ...Linear Servo Motors Recommended Linear Encoders and Cables 391 Cables and Peripheral Devices...
Page 435: ...ST2F Sigma Trac II Linear Stages 418 Sigma Trac II Linear Stages...
Page 495: ...SERVOPACKs 7W Two axis MECHATROLINK III Communications Reference SERVOPACKs 477 SERVOPACKs...
Page 516: ...SERVOPACKs SERVOPACK External Dimensions 498...
Page 547: ...SERVOPACK Cables 530 SERVOPACK Peripheral Devices 540 SERVOPACK Cables Peripherals...
Page 557: ...SERVOPACK Cables Peripherals SERVOPACK Cables 539 Cables and Peripheral Devices...
Page 599: ...Appendices Capacity Selection for Servo Motors 581 Appendices...
Page 615: ...Appendices Capacity Selection for Regenerative Resistors 597 Appendices...
Page 617: ...Appendices International Standards 599 Appendices...
Page 620: ......
Page 621: ......