YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
237
Table 2.37 Multi-step Speed Reference and MFDI Terminal Combinations
Related Parameters
Multi-Step Speed Reference 1
H1-xx = 3
Multi-Step Speed Reference 2
H1-xx = 4
Multi-Step Speed Reference 3
H1-xx = 5
Jog Reference
H1-xx = 6
Reference 1 (set in
b1-01
)
OFF
OFF
OFF
OFF
Reference 2 (
d1-02
or terminals
A1, A2)
ON
OFF
OFF
OFF
Reference 3 (
d1-03
or terminals
A1, A2)
OFF
ON
OFF
OFF
Reference 4 (
d1-04
)
ON
ON
OFF
OFF
Reference 5 (
d1-05
)
OFF
OFF
ON
OFF
Reference 6 (
d1-06
)
ON
OFF
ON
OFF
Reference 7 (
d1-07
)
OFF
ON
ON
OFF
Reference 8 (
d1-08
)
ON
ON
ON
OFF
Jog Reference (
d1-17
)
-
-
-
ON
*1
The Jog Frequency Reference (JOG command) overrides all other frequency references.
d1-01:
d1-02:
d1-03:
d1-04:
d1-05:
d1-06:
d1-07:
d1-08:
d1-17:
Figure 2.38 Time Chart for Multi-step Speed Reference/JOG Reference
■
d1-01: Reference 1
No.
(Hex.)
Name
Description
Default
(Range)
d1-01
(0280)
RUN
Reference 1
Sets the frequency reference in the units from
o1-03 [Frequency Display Unit Selection
.
0.00 Hz
(0.00 - 400.00 Hz)
V/f
OLV/PM
OLV/PM
EZOLV