YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
57
Setting Value
Function
Description
Ref.
7B
KEB Ride-Thru 2
Activate (N.O.)
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
7C
Short Circuit Braking (N.
O.)
Sets operation of Short Circuit Braking (N.O.).
ON : Short Circuit Braking is enabled.
OFF : Normal operation
Note:
When
A1-02 = 8 [Control Method Selection = EZOLV]
, this function is available only when you use a PM motor.
7D
Short Circuit Braking (N.
C.)
Sets operation of Short Circuit Braking (N.C.).
ON : Normal operation
OFF : Short Circuit Braking is enabled.
Note:
When
A1-02 = 8 [Control Method Selection = EZOLV]
, this function is available only when you use a PM motor.
82
PI Switch to Aux
Sets
YF-xx [PI Auxiliary Control]
parameters as primary PI loop parameters and disables
b5-xx [PID Control]
.
Note:
When this input is active,
YF-xx [PI Auxiliary Control]
parameters will always be the primary PI loop parameters.
Parameter
YF-20 [PI Aux Main PI Speed Control]
does not have an effect.
83
Dedicated Multi-Setpoint
YA-02
Sets the function to set the PID setpoint to
YA-02 [Setpoint 2]
.
Note:
If you use this function and one of
H1-xx = 3E or 3F [PID Setpoint Selection 1 or 2]
at the same time, the drive
will detect an
oPE03 [Multi-Function Input Setting Err]
.
ON :
YA-02
is PID setpoint.
OFF :
YA-01 [Setpoint 1]
,
YA-03 [Setpoint 3]
, or
YA-04 [Setpoint 4]
is PID setpoint.
84
Dedicated Multi-Setpoint
YA-03
Sets the function to set the PID setpoint to
YA-03 [Setpoint 3]
. Set this function and
H1-xx = 83 [Dedicated Multi-
Setpoint YA-02]
at the same time.
Note:
If you use this function and one of
H1-xx = 3E or 3F [PID Setpoint Selection 1 or 2]
at the same time, the drive
will detect an
oPE03 [Multi-Function Input Setting Err]
.
ON :
YA-03
is PID setpoint.
OFF :
YA-01 [Setpoint 1]
,
YA-02 [Setpoint 2]
, or
YA-04 [Setpoint 4]
is PID setpoint.
85
Dedicated Multi-Setpoint
YA-04
Sets the function to set the PID setpoint to
YA-04 [Setpoint 4]
. Set this function,
H1-xx = 83 [Dedicated Multi-Setpoint
YA-02]
, and
H1-xx = 84 [Dedicated Multi-Setpoint YA-03]
at the same time.
Note:
If you use this function and one of
H1-xx = 3E or 3F [PID Setpoint Selection 1 or 2]
at the same time, the drive
will detect an
oPE03 [Multi-Function Input Setting Err]
.
ON :
YA-04
is PID setpoint.
OFF :
YA-01 [Setpoint 1]
,
YA-02 [Setpoint 2]
, or
YA-03 [Setpoint 3]
is PID setpoint.
88
Thermostat Fault
Sets the drive to show the
VLTS [Thermostat Fault]
when the input terminal is ON.
Note:
This function is active when the drive is running.
90
DWEZ Digital Input 1
Sets digital input 1 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
91
DWEZ Digital Input 2
Sets digital input 2 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
92
DWEZ Digital Input 3
Sets digital input 3 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
93
DWEZ Digital Input 4
Sets digital input 4 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
94
DWEZ Digital Input 5
Sets digital input 5 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
95
DWEZ Digital Input 6
Sets digital input 6 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
96
DWEZ Digital Input 7
Sets digital input 7 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV