YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
43
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
E1-11
(030A)
Expert
Mid Point B Frequency
Sets a middle output frequency for the V/f pattern.
0.0 Hz
(0.0 - E1-04)
E1-12
(030B)
Expert
Mid Point B Voltage
Sets a middle point voltage for the V/f pattern.
0.0 V
(208 V Class: 0.0 - 255.0
V,
480 V Class: 0.0 - 510.0
V)
E1-13
(030C)
Expert
Base Voltage
Sets the base voltage for the V/f pattern.
0.0 V
(208 V Class: 0.0 - 255.0
V,
480 V Class: 0.0 - 510.0
V)
◆
E2: Motor Parameters
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
E2-01
(030E)
Motor Rated Current
(FLA)
Sets the motor rated current in amps.
Determined by o2-04
(10% to 200% of the
drive rated current)
E2-02
(030F)
Motor Rated Slip
Sets motor rated slip.
Determined by o2-04
(0.000 - 20.000 Hz)
E2-03
(0310)
Motor No-Load Current
Sets the no-load current for the motor in amps when operating at the rated frequency and
the no-load voltage.
Determined by o2-04
(0 to E2-01)
E2-04
(0311)
Motor Pole Count
Sets the number of motor poles.
4
(2 - 120)
E2-05
(0312)
Motor Line-to-Line
Resistance
Sets the line-to-line resistance for the motor stator windings.
Determined by o2-04
(0.000 - 65.000 Ω)
E2-06
(0313)
Motor Leakage
Inductance
Sets the voltage drop from motor leakage inductance when the motor is operating at the
rated frequency and rated current. This value is a percentage of Motor Rated Voltage.
Determined by o2-04
(0.0 - 60.0%)
E2-10
(0317)
Motor Iron Loss
Sets the motor iron loss.
Determined by o2-04
(0 - 65535 W)
E2-11
(0318)
Motor Rated Power
Sets the motor rated output in the units from
o1-58 [Motor Power Unit Selection]
.
Determined by o2-04
(0.00 - 650.00 HP)
◆
E3: V/f Pattern for Motor 2
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
E3-01
(0319)
Motor 2 Control Mode
Selection
Sets the control method for motor 2.
Note:
•
Parameter
L1-01 [Motor Overload (oL1) Protection]
sets the protection operation of
oL1 [Motor Overload]
the same as Motor 1.
•
When you use parameter
A1-03 [Initialize Parameters]
to initialize the drive, this
parameter is not reset.
0 : V/f Control
0
(0)
E3-04
(031A)
Motor 2 Maximum
Output Frequency
Set the maximum output frequency for the motor 2 V/f pattern.
Determined by E3-01
(40.0 - 400.0 Hz)
E3-05
(031B)
Motor 2 Maximum
Output Voltage
Sets the maximum output voltage for the motor 2 V/f pattern.
Determined by E3-01
(208 V Class: 0.0 - 255.0
V,
480 V Class: 0.0 - 510.0
V)
E3-06
(031C)
Motor 2 Base Frequency
Sets the base frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
E3-07
(031D)
Motor 2 Mid Point A
Frequency
Sets a middle output frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV