2-54
INSP
ADJ
FUSE INSPECTION
3. Replace:
• Blown fuse
Replacing steps:
• Turn the main switch off.
• Install a new fuse of the correct amperage.
• Turn the main switch on and verify if the electri-
cal circuit is operational.
• If the fuse immediately blows again, check the
electrical circuit.
*1
: FX10MT/FX10MTR/FX10MTRA
WARNING
Never use a fuse with an amperage other than
that specified. Improvising or using a fuse with
the wrong amperage rating may cause exten-
sive damage to the electrical system, cause the
lighting, ignition, grip warmer, signal and meter
systems to malfunction and could possibly
cause a fire.
Item
Amperage
Q’ty
1
Main fuse
40 A
1
2
Fuel injection
system fuse
10 A
1
3
Headlight fuse
20 A
1
4
Signal fuse
3 A
1
5
Auxiliary DC
jack fuse
*1
3 A
1
6
Ignition fuse
20 A
1
7
Radiator fan
motor fuse
10 A
1
8
Reserve fuse
20 A
10 A
3 A
1
2
1
8
1
2
6
7
4
8
5
3