I. Parameters
Parameter
Description
Adjustable Range
Factory
Unit
User´s
Page
Setting
Setting
P000
Access Parameter
0 to 999
0
-
77
READ ONLY PARAMETERS P001 to P099
P001
Soft-Starter Current
0 to 999.9
-
%
78
(%In of the Soft-Starter)
P002
Motor Current (%In of the Motor)
0 to 999.9
-
%
78
P003
Motor Current
0 to 9999.9
-
A
78
P004
Power Supply Voltage
0 to 999
-
V
78
P005
Network Frequency
0 to 99.9
-
Hz
78
P006
Soft-Starter Status
0=rdy - ready
-
-
78
1=Sub - Sub
2=Exx - Error
3=ruP - Run Up
4=FuLL - Full Volt.
5=PASS - By-pass
6=ECO - Reserved
7=rdo - Run Down
8=br - Braking
9=rE - FWD/REV
10=JOG - JOG
11=dly - Delay P630
12=G.di - Gen. Disable
P007
Output Voltage
0 to 999
-
V
79
P008
Power Factor
0 to 1.00
-
-
79
P009
Motor Torque (% Tn of the Motor)
0 to 999.9
-
%
79
P010
Output Power
0 to 6553.5
-
kW
79
P011
Apparent Output Power
0 to 6553.5
-
kVA
79
P012
Digital Input Status Dl1 to Dl6
0 = Inactive
-
-
80
1 = Active
P013
Status RL1, RL2 and RL3
0 = Inactive
-
-
80
1 = Active
P014
Last Fault
03 to 77
-
-
81
P015
Second Previous Fault
03 to 77
-
-
81
P016
Third Previous Fault
03 to 77
-
-
81
P017
Fourth Previous Fault
03 to 77
-
-
81
P023
Software Version
X.XX
-
-
81
P030
Current of Phase R
0 to 9999.9
-
A
81
P031
Current of Phase S
0 to 9999.9
-
A
81
P032
Current of Phase T
0 to 9999.9
-
A
81
P033
R-S Line Voltage
0 to 999
-
V
81
P034
S-T Line Voltage
0 to 999
-
V
81
P035
T-R Line Voltage
0 to 999
-
V
81