![WEG SSW-06.0085 User Manual Download Page 118](http://html.mh-extra.com/html/weg/ssw-06-0085/ssw-06-0085_user-manual_950611118.webp)
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
119
Range
[Factory Setting]
Parameter
Unit
Description / Notes
Table 6.39 -
Thermal Protection Time for hot motor
Class
3xIn
5xIn
7xIn
40
47.2s
16.8s
8.5s
30
35.4s
12.6s
6.4s
10
11.8s
4.2s
2.1s
20
23.6s
8.4s
4.2s
Current in % of In of the Motor
Factor
0%(cold)
1
20%
0,87
40%
0,74
60%
0,61
80%
0,48
100% (rated load)
0,35
Table 6.40 -
Multiplication Factor of the Cold Thermal Classes Time to obtain
Hot Thermal Class Times
Figure 6.29
– Thermal Protection Classes for hot motor with 100% In
Class 45
Class 40
Class 35
Class 30
Class 25
Class 20
Class 15
Class 10
Class 5
Current
x In
9x
8x
7x
6x
5x
4x
3x
2x
1x
1
10
100
1000
Time
t(s)
0,1