CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
105
Range
[Factory Setting]
Parameter
Unit
Description / Notes
Defines the action to be adopted when some errors relating to the
Serial or Fieldbus Communication occur.
For more information refer to the Serial Communication Manual and/
or to the Fieldbus Communication Manual for the Soft-Starter SSW-06.
NOTE!
When Serial Communication or Fieldbus Communication is not
used, this parameter must remain at 0 (not used).
Allows time programming for the fault detection during the serial
Modbus-RTU communication. So you can adopt an action when, for
instance, the communication with the master of the Modbus-RTU
network is lost.
For more information, refer to the Soft-Starter SSW-06 Fieldbus
Communication Manual.
NOTE!
This parameter must remain at 0 (not used), when the serial
communication is not being used.
P314
(1)
0 to 999
Timeout Time for
[ 0=not used ]
Serial Communication
1s
Telegram Reception
This parameter allows selecting the number of the first parameter to
be selected, which content will be sent from the Soft-Starter SSW-06
to the Master of the Fieldbus network.
For more details, refer to the Soft-Starter SSW-06 Fieldbus
Communication Manual.
P315
(1)
0 to 999
Read Parameter
[ 0 ]
via Fieldbus 1
1
This parameter allows selecting the number of the second parameter
to be selected, which content will be sent from the Soft-Starter SSW-06
to the Master of the Fieldbus network.
For more details, refer to the Soft-Starter SSW-06 Fieldbus
Communication Manual.
P316
(1)
0 to 999
Read Parameter
[ 0 ]
via Fieldbus 2
1
This parameter allows selecting the number of the third parameter to
be selected, which content will be sent from the Soft-Starter SSW-06
to the Master of the Fieldbus network.
For more details, refer to the Soft-Starter SSW-06 Fieldbus Communication
Manual.
P317
(1)
0 to 999
Read Parameter
[ 0 ]
via Fieldbus 3
1