![WEG SSW-06.0085 User Manual Download Page 55](http://html.mh-extra.com/html/weg/ssw-06-0085/ssw-06-0085_user-manual_950611055.webp)
CHAPTER 3 - INSTALLATION AND CONNECTION
55
3.3.11 Recommended Setup with Command via Digital Inputs and DC-Braking
Figure 3.32 -
Recommended Setup with Command via Digital Inputs and DC-Braking.
3.3.12 Recommended Setup with Command via Digital Inputs and External By-pass Contactor
Figure 3.33 -
Recommended Setup with Command via Digital Inputs and External By-pass
Contactor.
P265
=1
P264
=1
P230
=1
P220
=1
P266
=5
P277
=1
P279
=6
P500
=3
P278
=5
P264
=1
P230
=1
P220
=1
P140
=1
P277
=1
P278
=3
P279
=6
+ t
o
M
3~
R
S
T
PE
K1
R S T
1 2 P E
33 34
X1E
X1A
18
19
RL1
RL2
20
21 22 23 24
RL3
X1C
X1B
Dl1
3
Dl2
4
Dl3
5
Dl4
6
Dl5
7
COM
8 9
0V
10
24V
11
PTC
B A
12 13
U V W
Fault
T1
K1
PTC
E
n
a
b
le
D
is
a
b
le
K2
W
it
h
o
u
t
B
ra
k
in
g
G
e
n
.
E
n
a
b
le
K2
+ t
o
M
3~
R
S
T
PE
K1
R S T
1 2 P E
33 34
X1E
X1A
18
19
RL1
RL2
20
21
22 23 24
RL3
X1C
X1B
Dl1
3
Dl2
4
Dl3
5
Dl4
6
Dl5
7
COM
8 9
0V
10
24V
11
PTC
B A
12 13
U V W
Fault
T1
K1
PTC
E
n
a
b
le
D
is
a
b
le
K2
K2
X1D
27
28
29
30
31
32
R
e
d
B
la
c
k
B
la
c
k
R
e
d
B
la
c
k
R
e
d
See note 3.3
See note 3.3
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]