P3.06 is used to set the DC braking start frequency during stopping.
P3.07 is used to set the DC braking current value. This value is presented as the percentage of inverter
rated current. It ranges from 0.0 ~ 90.0% to in variable torque series.
P3.08 is used to set the active time of the DC braking current.
For some production equipment, reverse running may cause equipment damage. This function can be
used to prevent reverse running.
When the motor running direction is opposite to the required direction of the equipment, the wire
connection of any two terminals at the inverter output to motor can be interchanged so that the run
forward direction of the equipment is consistent with the run forward direction defined by the inverter.
This parameter is used to realize the waiting time for the zero crossing of rotation speed when the
inverter switches from forward running to reverse running (or from reverse running to forward running).
输出频率
时间
P3.T0
Output frequency
Time
输出频率
时间
P3.T0
Output frequency
Time
Figure6−TT ForwardTreverse dead zone time
P3.TT is the frequency set for jog operation.
Jog acceleration time P3.TT: The time from zero to maximum frequency (P0.TT).
Jog deceleration time P3.T3: The time from maximum frequency (P0.TT) to zero.
When the inverter is in standby status, it can adopt jog operation. The jog operation command may
come from the operation panel, multi−function terminal or host computer.
Note:
The jog function is disabled under torque control.
0.0 ~ 3600.0 s (0.0s)
P3.T0
ForwardTreverse switch-over dead zone time
0.T ~ 60.0 s (T0.0s)
Jog deceleration time
P3.T3
0.T ~ 60.0 s (T0.0s)
Jog acceleration time
P3.TT
0.T0 ~ 50.00 Hz (5.00Hz)
Jog frequency
P3.TT
0 ~ T(0)
RUN reverse selection
P3.09
0.0 ~ 30.0 s (0.0s)
DC braking active time
P3.08
0.0 ~ TT0.0 %( 0.0%)
DC braking current
P3.07
0.00 ~ 300.00 Hz (0.00Hz)
DC braking start frequency
P3.06
Summary of Contents for E5 Series
Page 1: ...E5 Series High Performance Universal Inverter USER S MANUAL E5 Series USER S MANUAL ...
Page 7: ...vi T Setting Process for Open Loop ...
Page 8: ...vii Open loop setting process continued ...
Page 9: ...viii 3 Setting Process for Closed Loop ...
Page 10: ...ix Setting Process for Closed Loop continued ...