6.T9 Special Parameters for EX-DT0T (Group HT)
If EX-DT0T card is installed, HT.00 should be set to T to enable the function of EX-DT0T.
X8 ~ XTT terminal function and XT ~ X7 terminal function are identical, refer to P5.00 to P5.07 for description.
The parameter is used to set the X8 to XTT virtual terminal. Set to “0” is disabled and “T” is enabled .
X8 ~ XTT terminal positive logic or negative logic selection
0: Active if current flowing through, positive logic
T: Active if no current flowing through, negative logic
bit0
X8 positive logic or negative logic selection
bitT
X9 positive logic or negative logic selection
bitT
XT0 positive logic or negative logic selection
bit3
XTT positive logic or negative logic selection
RAT ~ RA3 terminal function and RA terminal function are identical, refer to P7.0T for description.
The parameter is used to set the RAT to RA3 virtual terminal. Set to “0” is disabled and “T” is enabled .
RAT ~ RA3 terminal positive logic or negative logic selection
0: Active if in magnetizing status, positive logic
T: Active if not in magnetizing status, negative logic
bit0
RAT positive logic or negative logic selection
bitT
RAT positive logic or negative logic selection
bitT
RA3 positive logic or negative logic selection
0.0 ~ 999.9s (0.0s)
RA3 output function action delay time
HT.T5
0.0 ~ 999.9s (0.0s)
RAT output function action delay time
HT.T4
0.0 ~ 999.9s (0.0s)
RAT output function action delay time
HT.T3
0 ~ 7 (0)
RAT ~ RA3 terminal positive logic or negative logic selection
HT.TT
0 ~ T (0)
RAT ~ RA3 virtual terminal active selection
HT.TT
00 ~ 47 (0T)
Relay RA3 output function selection
HT.T0
00 ~ 47 (0T)
Relay RAT output function selection
HT.09
00 ~ 47 (00)
Relay RAT output function selection
HT.08
0 ~ F (0)
X8 ~ XTT terminal positive logic or negative logic selection
HT.07
0 ~ T (0)
X8 ~ XTT virtual terminal active selection
HT.06
0.000 ~ T.000s (0.00Ts)
X8 to XTT terminal filter time
HT.05
00 ~ 99(99)
XTT terminal input function selection
HT.04
00 ~ 99(99)
XT0 terminal input function selection
HT.03
00 ~ 99(99)
X9 terminal input function selection
HT.0T
00 ~ 99(99)
X8 terminal input function selection
HT.0T
0 ~ T(T)
EX-DT0T digital terminal extension card selection
HT.00
Summary of Contents for E5 Series
Page 1: ...E5 Series High Performance Universal Inverter USER S MANUAL E5 Series USER S MANUAL ...
Page 7: ...vi T Setting Process for Open Loop ...
Page 8: ...vii Open loop setting process continued ...
Page 9: ...viii 3 Setting Process for Closed Loop ...
Page 10: ...ix Setting Process for Closed Loop continued ...