E5 Series High Performance Universal Inverter User’s Manual
110
Chapter 6 Parameter Descriptions
6.T3 Communication Parameters (Group PC)
Note:
Terminal 485 only available for “E5−H−4T**G−63”, “E5−H−4T**G−34” non−standard series and E5−A
series. So group PC is used for above series.
The inverter supports international Modbus RTU protocol. Refer to the appendix A.
PC.00 is used to set the communication baud rate.
4: 4800bps
5: 9600bps
6: T9T00bps
7: 38400bps
8: 57600bps
PC.0T is used to set communication format, odd−even check.
0: T−8−T format, without check
T: T−8−T format, even check
T: T−8−T format, odd check
PC.0T is used to set the local address. Broadcast address is “0”, slave address range is “T~T47”,
“T48~T55” is reserved.
Ones place: Terminal RS485 setting
bit0
0: Without reply
T: Reply if communication with host computer
bitT
0: No reply if communication disconnected
T: Reply if communication disconnected
bitT
0: Communication will not detect password
T: Communication will detect password
bit3
0: 0x06 and 0xT0 command communication write data in RAM
T: 0x06 and 0xT0 command communication write data to EEPROM
Tens place: Reserved
Hundreds place: Operation panel RS485 setting: Same as ones place
Note:
If change parameter through communication frequently, it is suggest setting PC.03 to 303 to write data in
RAM.
000 ~ F0F(303)
Communication parameters setting
PC.03
T ~ T47(T)
Local address
PC.0T
0 ~ T(0)
Data format
PC.0T
4 ~ 8(5)
Communication baud rate
PC.00
Summary of Contents for E5 Series
Page 1: ...E5 Series High Performance Universal Inverter USER S MANUAL E5 Series USER S MANUAL ...
Page 7: ...vi T Setting Process for Open Loop ...
Page 8: ...vii Open loop setting process continued ...
Page 9: ...viii 3 Setting Process for Closed Loop ...
Page 10: ...ix Setting Process for Closed Loop continued ...