E5 Series High Performance Universal Inverter User’s Manual
Chapter 6 Parameter Descriptions
59
Chapter 6 Parameter Descriptions
6.T Basic Function Parameters (Group P0)
In order to prevent the irrelevant personnel from querying and changing the parameters, and protect
your know-how, it is possible to restrict access to the parameters by setting user password.
No password protection by default, All the parameters in Zone P can be queried and changed.
Setting password:
Enter four digits as user password, and press PRG key for confirmation. Repeat this operation once
again. When “P.Set” is displayed, the password is successfully set.
Change password:
Press PRG key to enter the password verification status, and “0.0.0.0.” is displayed. Enter correct
password, and it enters parameter editing status. Select P0.00 (parameter P0.00 displayed as 0000) and
then enter new password and press PRG key for confirmation. Set the same password for P0.00 twice.
When “P.Set” is displayed, the new password is successfully set.
Cancel password:
Press PRG key to enter the password verification status, and “0.0.0.0.” is displayed. Enter correct user
password to enter the parameter editing status, check if P0.00 is 0000. Press PRG key for confirmation,
and set P0.00=0000 again, and then “P.Clr” is displayed and the password is canceled.
Note:
For the method of activating the password, refer to 4.5 Password Operation in Chapter 4.
This parameter is used to set the modification authority and initialization level of the parameters.
0: All the parameters are allowed for modification.
T: All the parameters are disallowed for modification.
T: Restore all the parameters in zone P to factory setting.
3: Restore all the parameters in zone P to factory setting except for the motor parameters (group P9).
4: Restore all the parameters in zone P and zone A to factory setting.
5: Restore all the parameters to factory setting except group d.
Note:
The password P0.00 will be cleared after the parameters are restore to factory setting.
This parameter is use to set parameters display mode to improve the work efficiency according to actual
requirement of the work-site.
0: Basic menu mode: The operation panel can display all the parameters.
T: Fast menu mode: The operation panel only display the fast parameters defined by the manufacturer.
T: Non factory setting menu mode: The operation panel only display the parameters different from the
factory setting.
0 ~ 3(0)
Parameters display mode
P0.0T
0 ~ 5(0)
Parameters protection
P0.0T
0000 ~ FFFF (0000)
User password
P0.00
Summary of Contents for E5 Series
Page 1: ...E5 Series High Performance Universal Inverter USER S MANUAL E5 Series USER S MANUAL ...
Page 7: ...vi T Setting Process for Open Loop ...
Page 8: ...vii Open loop setting process continued ...
Page 9: ...viii 3 Setting Process for Closed Loop ...
Page 10: ...ix Setting Process for Closed Loop continued ...