E5 Series High Performance Universal Inverter User’s Manual
Chapter 6 Parameter Descriptions
95
changes, before the integral value catch up that change trend, it needs to take longer time to offset the
effect brought by the continuous integral .
If the output value of the close loop regulation is inconsistent with the current setup running direction, the
close loop output value has two actions for selection.
0: Must be consistent with preset direction: When the output value of the close loop regulation is
inconsistent with the current setup running direction, the current output value will be forced to be 0
internally.
T: Can regulation to reverse to preset direction: When the output value of the close loop adjustment is
inconsistent with the current preset running direction, the close loop regulation opposite to the current
preset running direction will be executed.
PID is positive function by default. If negative function is required, such as if feedback value is greater
than reference value and the frequency needed increase, this parameter should be used or the function
of multi−function terminal function is set to “68”.
P8.09=0, terminal function is disabled: positive
P8.09=T, terminal function is enabled: positive
P8.09=T, terminal function is disabled: negative
P8.09=0, terminal function is enabled: negative
This parameter is used to set the PID regulation acceleration and deceleration time.
Note:
This parameter is only available for “E5−H−4T**G−63” non−standard series and E5−A series.
0.0 ~ 6553.5 s (T0.0s)
PID acceleration T deceleration time
P8.T0
0 ~ T (0)
PID positive or negative function
P8.09
Summary of Contents for E5 Series
Page 1: ...E5 Series High Performance Universal Inverter USER S MANUAL E5 Series USER S MANUAL ...
Page 7: ...vi T Setting Process for Open Loop ...
Page 8: ...vii Open loop setting process continued ...
Page 9: ...viii 3 Setting Process for Closed Loop ...
Page 10: ...ix Setting Process for Closed Loop continued ...