Parameterizing and Configuring
Configuring the devices at EtherNet/IP
110
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.8.6
EtherNet/IP standard classes
The modules support the following EtherNet/IP standard classes in accordance with the CIP
specification.
Class code
Object name
Dec.
Hex.
01
0x01
04
0x04
Assembly Object [
06
0x06
245
0xF5
TCP/IP Interface Object [
246
0xF6
Ethernet Link Object [
Identity Object (0x01)
The following description of the Ethernet Link Object is taken from the CIP specification, Vol. 2,
Rev. 2.1 by ODVA & ControlNet International Ltd. and adapted to the Turck products.
Instance attributes
Attribute no.
Attribute
name
Get/set
Type
Value
Dec.
Hex.
1
0x01
Vendor ID
G
UINT
Contains the manufacturer ID.
Turck = 0x46
2
0x02
Product
type
G
UINT
Shows the general product type.
Communications Adapter 12
dez
=
0x0C
3
0x03
Product
code
G
UINT
Identifies a special product in a
device type.
default: 27247
dec
= 6A6F
4
0x04
Revision
n
Major
n
Minor
G
STRUCT OF:
n
USINT
n
USINT
Revision of the device which is rep-
resented by the Indentity Object.
n
0x01
n
0x06
5
0x05
Device
status
G
WORD
WORD
6
0x06
Serial
number
G
UDINT
Contains the identification number
of the product (the last 3 bytes of the
MAC-ID).
7
0x07
Product
name
G
STRUCT OF:
USINT
STRING [13]
i.e.: TBEN-S2-4IOL
Device Status
Bit
Name
Definition
0…1
reserved
default = 0
2
Configured
TRUE = 1:
The application in the device has been con-
figured (default setting).
3
reserved
default = 0