V04.00 | 2021/05
183
2…10 V
Diagnostics
decimal
hexadecimal
(two's complement)
Voltage value U
M
= (dec. Value × 2.441 × 10
-4
) V + 2 V
> 10.1000 V
"Upper limit value exceeded” ON
32767
7FFF
< 10.0500 V
"Upper limit value exceeded" OFF
32767
7FFF
10.0000 V
Nominal range
32767
7FFF
9.999 V
32766
7FFE
9.992 V
32736
7FE0
2.0004 V
16
0010
2.0 V
0
0000
> 1.95 V
"Lower limit value underrun" OFF
0
0000
< 1.90 V
"Lower limit value underrun" ON
0
0000
> 1.5 V
"Wire break" OFF
0
0000
< 1.45 V
"Wire break" ON
0
0000
0…5 V
Diagnostics
decimal
hexadecimal
(two's complement)
Voltage value U
M
= (dec. value × 1.526 × 10
-4
) V
> 5.1000 V
"Upper limit value exceeded” ON
32767
7FFF
< 5.0500 V
"Upper limit value exceeded" OFF
32767
7FFF
5.0000 V
Nominal range
32767
7FFF
4.999 V
32766
7FFE
4.995 V
32736
7FE0
0.002 V
16
0010
0 V
0
0000
> -0.05 V
"Lower limit value underrun" OFF
0
0000
< -0.10 V
"Lower limit value underrun" ON
0
0000
1…5 V
Diagnostics
decimal
hexadecimal
(two's complement)
Voltage value U
M
= (dec. Value × 1.2207 × 10
-4
) V + 1 V
> 5.1000 V
"Upper limit value exceeded” ON
32767
7FFF
< 5.0500 V
"Upper limit value exceeded" OFF
32767
7FFF
5.0000 V
Nominal range
32767
7FFF
4.999 V
32766
7FFE
4.996 V
32736
7FE0
1.002 V
16
0010
1.000 V
0
0000
> 0.95 V
"Lower limit value underrun" OFF
0
0000
< 0.90 V
"Lower limit value underrun" ON
0
0000
> 0.75 V
"Wire break" OFF
0
0000
< 0.70 V
"Wire break" ON
0
0000