Class 152 (0x98) – Basic
This class data and parameters for the device’s basic functions.
Applies to:
n
TBEN-S1-4DIP-4DOP
Attribute no.
Designation
Get/
Set
Type
Meaning
Dec.
Hex.
Parameters
1
0x01
Manual reset after
overcurr. ch4
G/S
USINT
0: no
1: yes
2
0x02
Manual reset after
overcurr. ch5
G/S
USINT
0: no
1: yes
3
0x03
Manual reset after
overcurr. ch6
G/S
USINT
0: no
1: yes
4
0x04
Manual reset after
overcurr. ch7
G/S
USINT
0: no
1: yes
5
0x05
Overcurrent VAUX1 ch0…3
G
USINT
0: -
1: active
6
0x06
Overcurrent VAUX1 ch4…7
G
USINT
0: -
1: active
7
0x07
Diagnostics ch4 – overcurrent
G
USINT
0: -
1: active
8
0x08
Diagnostics ch5 – overcurrent
G
USINT
0: -
1: active
9
0x09
Diagnostics ch6 – overcurrent
G
USINT
0: -
1: active
10
0x0A
Diagnostics ch7 – overcurrent
G
USINT
0: -
1: active
11
0x0B
Input value ch0
G
USINT
0: off
1: on
12
0x0C
Input value ch1
G
USINT
0: off
1: on
13
0x0D
Input value ch2
G
USINT
0: off
1: on
14
0x0E
Input value ch3
G
USINT
0: off
1: on
15
0x0F
Output
G
BYTE
Bit 0: Output value ch4
bit 1: Output value ch5
bit 2: Output value ch6
bit 3: Output value ch7