Parameterizing and Configuring
Configuring the devices at EtherNet/IP
150
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Class 151 (0x97) – Basic
This class data and parameters for the device’s basic functions.
Applies to:
n
TBEN-S1-8DXP
Attribute no.
Designation
Get/
Set
Type
Meaning
Dec.
Hex.
Parameters
1
0x01
Activate output ch0
G/S
USINT
0: no
1: yes
2
0x02
Activate output ch1
G/S
USINT
0: no
1: yes
3
0x03
Activate output ch2
G/S
USINT
0: no
1: yes
4
0x04
Activate output ch3
G/S
USINT
0: no
1: yes
5
0x05
Activate output ch4
G/S
USINT
0: no
1: yes
6
0x06
Activate output ch5
G/S
USINT
0: no
1: yes
7
0x07
Activate output ch6
G/S
USINT
0: no
1: yes
8
0x08
Activate output ch7
G/S
USINT
0: no
1: yes
9
0x09
Manual reset after
overcurr. ch0
G/S
USINT
0: no
1: yes
10
0x0A
Manual reset after
overcurr. ch1
G/S
USINT
0: no
1: yes
11
0x0B
Manual reset after
overcurr. ch2
G/S
USINT
0: no
1: yes
12
0x0C
Manual reset after
overcurr. ch3
G/S
USINT
0: no
1: yes
13
0x0D
Manual reset after
overcurr. ch4
G/S
USINT
0: no
1: yes
14
0x0E
Manual reset after overcurr. ch5
G/S
USINT
0: no
1: yes
15
0x0F
Manual reset after overcurr. ch6
G/S
USINT
0: no
1: yes
16
0x10
Manual reset after overcurr. ch7
G/S
USINT
0: no
1: yes
17
0x11
Overcurrent VAUX1 ch0…3
G
USINT
0: -