105
S
ECTION
3 - L
EVEL
II M
ODULE
R
EPLACEMENT
/ D
IAGNOSTIC
S
TATUS
AND
T
ESTING
Section 3
LED D
EVICE
S
TATUS
Refer to Figure 3-91. Red and Green sta-
tus LEDs can be viewed on the backside of
the T5 EPP assembly. They are used to dis-
play the current operational status of the
T5 EPP's internal (fi rmware) or external
command (software) state. Refer to Figure
3-92 for the complete LED status table.
The basic operational status of the T5 EPP
can be verifi ed in the following ways:
P
OWER
O
N
AND
T
ERMINAL
S
OFTWARE
I
NITIALIZATION
S
TATUS
1. Push the AC pow er ON/OFF switch to the ON(I) position.
2. The green and red LEDs should briefl y turn on. (The EPP fi rmware is initializ-
ing.) Immediately following, the green LED should be fl ashing at a slow 1 HZ
rate and the red LED fl ashing at a fast 2 HZ rate (EPP fi rmware has initialized
and is waiting for the fi rst command). Both LEDs should turn off when the
EPP (SPED) is initialized by the terminal software (EPP application is ready).
M
ANAGEMENT
F
UNCTIONS
L
OG
O
N
S
TATUS
1. Press Ctrl (Blank) + 1 keys to log into Management Functions.
2. Verify the green LED is off and the red LED is fl ashing at the fast 2 HZ rate
(EPP is in the Unsecure, Clear Text Entry Mode).
E
NTER
M
ASTER
K
EYS
OR
C
HANGE
M
ASTER
K
EYS
P
ASSWORD
S
TATUS
1. Enter Key Management and press the Enter Master Keys button (or press the
Change Passwords button, followed by either the User 1 Password or User 2
Password button).
2. Verify the green LED is off and the red LED is on and not fl ashing (EPP is in
the Secure, Key Entry or Password Entry Mode).
E
NTER
C
USTOMER
T
RANSACTIONS
PIN N
UMBER
1. Enter Customer Transactions. (If Customer Transactions is entered from
Management Functions, the red LED will fl ashing at the fast 2 HZ rate. If it is
entered directly from power up, both status LEDs should be off.)
2. Perform a transaction, e.g., withdrawal. When the PIN number prompt ap-
pears, the green LED should be off and the red LED should be on (Secure,
PIN Entry Mode).
Initializing SPED...
SPED Version SP-XX-XX-XX-XXX
Figure 3-91. Location of the T5 EPP Status
LEDs and the replaceable battery
Status LEDs
Battery
Summary of Contents for RL5000
Page 2: ...ii RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL...
Page 14: ...xiv RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Preface...
Page 19: ...2 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 1...
Page 21: ...4 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 1...
Page 29: ...12 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 2...
Page 51: ...34 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 3...
Page 162: ...145 INDEX Index INDEX...